VIB-2026-003 — Photo Review
128 Defect · 0 Positive · 0 Inventory · 0 Excluded · unreviewed
📍 Segment Map (0 segments)
Photo 1
Excluded
1/128
14:00 IMG_1801.JPG
📍
🎤 Ok, I'm in front of the Ananda Gate. So there's a big drainage in front of the gate.
Photo 2
Excluded
2/128
14:03 IMG_1802.JPG
📍
🎤 Now I'm checking the pump room for the villa water. I can see two filters.
Photo 3
Excluded
3/128
14:03 IMG_1803.JPG
📍
🎤 I can see two pumps. I think one is broken and one is working.
Photo 4
Excluded
4/128
14:04 IMG_1804.JPG
📍
🎤 I can see two pumps. I think one is broken and one is working.
Photo 5
Excluded
5/128
14:04 IMG_1805.JPG
📍
🎤 There is also one profile tank in aluminium for water
Photo 6
Excluded
6/128
14:04 IMG_1806.JPG
📍
🎤 There is also one profile tank in aluminium for water
Photo 7
Excluded
7/128
14:05 IMG_1807.JPG
📍
🎤 Above Profil Tang there is an AC outdoor unit and above the outdoor unit there's a massive nest of wasps
Photo 8
Excluded
8/128
14:05 IMG_1808.JPG
📍
🎤 Above Profil Tang there is an AC outdoor unit and above the outdoor unit there's a massive nest of wasps
Photo 9
Excluded
9/128
14:05 IMG_1809.JPG
📍
🎤 The filters are non-functioning and not connected to electricity.
Photo 10
Excluded
10/128
14:06 IMG_1810.JPG
📍
🎤 The filters are non-functioning and not connected to electricity.
Photo 11
Excluded
11/128
14:06 IMG_1811.JPG
📍
🎤 The filters are non-functioning and not connected to electricity.
Photo 12
Excluded
12/128
14:06 IMG_1812.JPG
📍
🎤 The filters are non-functioning and not connected to electricity.
Photo 13
Excluded
13/128
14:07 IMG_1813.JPG
📍
🎤 Now I'm looking at the sub-panel for the whole villa which consists of only 6 MCBs and one MCB 63 is much higher than the MCB for PLN. So the installation, the…
Photo 14
Excluded
14/128
14:07 IMG_1814.JPG
📍
🎤 Now I'm looking at the sub-panel for the whole villa which consists of only 6 MCBs and one MCB 63 is much higher than the MCB for PLN. So the installation, the…
Photo 15
Excluded
15/128
14:08 IMG_1815.JPG
📍
🎤 Now I'm looking at the sub-panel for the whole villa which consists of only 6 MCBs and one MCB 63 is much higher than the MCB for PLN. So the installation, the…
Photo 16
Excluded
16/128
14:08 IMG_1816.JPG
📍
🎤 Now I'm looking at the sub-panel for the whole villa which consists of only 6 MCBs and one MCB 63 is much higher than the MCB for PLN. So the installation, the…
Photo 17
Excluded
17/128
14:09 IMG_1817.JPG
📍
🎤 Outdoor light in the planters and garden not properly connected with waterproof box.
Photo 18
Excluded
18/128
14:10 IMG_1818.JPG
📍
🎤 Outdoor ceilings in very average condition and cracked in some areas.
Photo 19
Excluded
19/128
14:10 IMG_1819.JPG
📍
🎤 They are bubbling, look like they've been fixed several times.
Photo 20
Excluded
20/128
14:10 IMG_1820.JPG
📍
🎤 They are bubbling, look like they've been fixed several times.
Photo 21
Excluded
21/128
14:10 IMG_1821.JPG
📍
🎤 They are bubbling, look like they've been fixed several times.
Photo 22
Excluded
22/128
14:10 IMG_1822.JPG
📍
🎤 They are bubbling, look like they've been fixed several times.
Photo 23
Excluded
23/128
14:11 IMG_1823.JPG
📍
🎤 They are bubbling, look like they've been fixed several times.
Photo 24
Excluded
24/128
14:12 IMG_1824.JPG
📍
🎤 Some outdoor ceiling also peeling in some parts.
Photo 25
Excluded
25/128
14:12 IMG_1825.JPG
📍
🎤 Some outdoor ceiling also peeling in some parts.
Photo 26
Excluded
26/128
14:12 IMG_1826.JPG
📍
🎤 Some outdoor ceiling also peeling in some parts.
Photo 27
Excluded
27/128
14:13 IMG_1827.JPG
📍
🎤 No sign of leakage just with the thermal imager. No leak.
Photo 28
Excluded
28/128
14:14 IMG_1828.JPG
📍
🎤 Okay, now I'm checking the pool deck. I can see that the pieces of wood are not stable and some are not fixed properly and they look like worn out.
Photo 29
Excluded
29/128
14:14 IMG_1829.JPG
📍
🎤 Okay, now I'm checking the pool deck. I can see that the pieces of wood are not stable and some are not fixed properly and they look like worn out.
Photo 30
Excluded
30/128
14:14 IMG_1830.JPG
📍
🎤 The deck in general should be revised because I think there must be like some rafters inside the deck that must be broken or like rotten.
Photo 31
Excluded
31/128
14:14 IMG_1831.JPG
📍
🎤 The deck in general should be revised because I think there must be like some rafters inside the deck that must be broken or like rotten.
Photo 32
Excluded
32/128
14:15 IMG_1832.JPG
📍
🎤 Now I'm looking at the deck, the pool that is being cleaned. Missing grouting on the steps. And lamps, okay. Filtration not working at the time of inspection.
Photo 33
Excluded
33/128
14:15 IMG_1833.JPG
📍
🎤 Now I'm looking at the deck, the pool that is being cleaned. Missing grouting on the steps. And lamps, okay. Filtration not working at the time of inspection.
Photo 34
Excluded
34/128
14:15 IMG_1834.JPG
📍
🎤 Now I'm looking at the deck, the pool that is being cleaned. Missing grouting on the steps. And lamps, okay. Filtration not working at the time of inspection.
Photo 35
Excluded
35/128
14:16 IMG_1835.JPG
📍
🎤 All grouting in the pool must be revised because a lot are missing.
Photo 36
Excluded
36/128
14:16 IMG_1836.JPG
📍
🎤 All grouting in the pool must be revised because a lot are missing.
Photo 37
Excluded
37/128
14:16 IMG_1837.JPG
📍
🎤 There's a carving on the wall facing the pool that has a lot of dirt and black, probably coming from not being maintained and because of the rain.
Photo 38
Excluded
38/128
14:16 IMG_1838.JPG
📍
🎤 There's a carving on the wall facing the pool that has a lot of dirt and black, probably coming from not being maintained and because of the rain.
Photo 39
Excluded
39/128
14:17 IMG_1839.JPG
📍
🎤 More pictures of the exterior house soffits with paint cracked and bubbling.
Photo 40
Excluded
40/128
14:17 IMG_1840.JPG
📍
🎤 More pictures of the exterior house soffits with paint cracked and bubbling.
Photo 41
Excluded
41/128
14:19 IMG_1841.JPG
📍
🎤 Sockets in the living room are not connected to ground.
Photo 42
Excluded
42/128
14:20 IMG_1842.JPG
📍
🎤 Regarding windows, the thing that holds the curtain is held by some pieces of string because it might be not strong enough to hold the curtains.
Photo 43
Excluded
43/128
14:21 IMG_1843.JPG
📍
🎤 No sign of humidity or resin damp, just wrong finishing along the walls.
Photo 44
Excluded
44/128
14:21 IMG_1844.JPG
📍
🎤 No sign of humidity or resin damp, just wrong finishing along the walls.
Photo 45
Excluded
45/128
14:21 IMG_1845.JPG
📍
🎤 No sign of humidity or resin damp, just wrong finishing along the walls.
Photo 46
Excluded
46/128
14:22 IMG_1846.JPG
📍
🎤 The floor of the living room is in OK condition.
Photo 47
Excluded
47/128
14:22 IMG_1847.JPG
📍
🎤 Stained walls in the living room with signs of dirty fingers and some scratches and some chips on the walls.
Photo 48
Excluded
48/128
14:22 IMG_1848.JPG
📍
🎤 Stained walls in the living room with signs of dirty fingers and some scratches and some chips on the walls.
Photo 49
Excluded
49/128
14:23 IMG_1849.JPG
📍
🎤 Stained walls in the living room with signs of dirty fingers and some scratches and some chips on the walls.
Photo 50
Excluded
50/128
14:23 IMG_1850.JPG
📍
🎤 Stained walls in the living room with signs of dirty fingers and some scratches and some chips on the walls.
Photo 51
Excluded
51/128
14:23 IMG_1851.JPG
📍
🎤 Cabinet under the TV with Wi-Fi equipment. Okay, no signs of termites.
Photo 52
Excluded
52/128
14:23 IMG_1852.JPG
📍
🎤 Cabinet under the TV with Wi-Fi equipment. Okay, no signs of termites.
Photo 53
Excluded
53/128
14:23 IMG_1853.JPG
📍
🎤 Cabinet under the TV with Wi-Fi equipment. Okay, no signs of termites.
Photo 54
Excluded
54/128
14:24 IMG_1854.JPG
📍
🎤 Water pressure in kitchen, good.
Photo 55
Excluded
55/128
14:24 IMG_1855.JPG
📍
🎤 Water pressure in kitchen, good.
Photo 56
Excluded
56/128
14:24 IMG_1856.JPG
📍
🎤 Water pressure in kitchen, good.
Photo 57
Excluded
57/128
14:25 IMG_1857.JPG
📍
🎤 Kitchen cabinets are old, some doors are not closing properly or not aligned. Same for the drawers.
Photo 58
Excluded
58/128
14:25 IMG_1858.JPG
📍
🎤 Kitchen cabinets are old, some doors are not closing properly or not aligned. Same for the drawers.
Photo 59
Excluded
59/128
14:25 IMG_1859.JPG
📍
🎤 Kitchen cabinets are old, some doors are not closing properly or not aligned. Same for the drawers.
Photo 60
Excluded
60/128
14:25 IMG_1860.JPG
📍
🎤 Kitchen cabinets are old, some doors are not closing properly or not aligned. Same for the drawers.
Photo 61
Excluded
61/128
14:26 IMG_1861.JPG
📍
🎤 Kitchen cabinets are old, some doors are not closing properly or not aligned. Same for the drawers.
Photo 62
Excluded
62/128
14:26 IMG_1862.JPG
📍
🎤 Old and basic gas stove.
Photo 63
Excluded
63/128
14:26 IMG_1863.JPG
📍
🎤 Old and basic gas stove.
Photo 64
Excluded
64/128
14:27 IMG_1864.JPG
📍
🎤 Old and basic gas stove.
Photo 65
Excluded
65/128
14:27 IMG_1865.JPG
📍
🎤 One socket in the kitchen broken.
Photo 66
Excluded
66/128
14:28 IMG_1866.JPG
📍
🎤 Other sockets not connected to ground in the kitchen.
Photo 67
Excluded
67/128
14:29 IMG_1868.JPG
📍
🎤 ACs in living room are at least 2 pk.
Photo 68
Excluded
68/128
14:30 IMG_1869.JPG
📍
🎤 ACs in living room are at least 2 pk.
Photo 69
Excluded
69/128
14:30 IMG_1870.JPG
📍
🎤 Flooring powder room stained and tile chipped.
Photo 70
Excluded
70/128
14:31 IMG_1871.JPG
📍
🎤 Flooring powder room stained and tile chipped.
Photo 71
Excluded
71/128
14:31 IMG_1872.JPG
📍
🎤 Flooring powder room stained and tile chipped.
Photo 72
Excluded
72/128
14:31 IMG_1873.JPG
📍
🎤 Flooring powder room stained and tile chipped.
Photo 73
Excluded
73/128
14:31 IMG_1874.JPG
📍
🎤 Flooring powder room stained and tile chipped.
Photo 74
Excluded
74/128
14:31 IMG_1875.JPG
📍
🎤 Parallel room facet wobbling.
Photo 75
Excluded
75/128
14:32 IMG_1876.JPG
📍
🎤 Drain of the powder room sink is not with siphon.
Photo 76
Excluded
76/128
14:32 IMG_1877.JPG
📍
🎤 Drain of the powder room sink is not with siphon.
Photo 77
Excluded
77/128
14:33 IMG_1878.JPG
📍
🎤 Some sockets in living room are not well fixed on the wall.
Photo 78
Excluded
78/128
14:33 IMG_1879.JPG
📍
🎤 The socket that is not fixed is not working.
Photo 79
Excluded
79/128
14:34 IMG_1880.JPG
📍
🎤 Handles and fixtures of the sliding doors are old and worn out.
Photo 80
Excluded
80/128
14:34 IMG_1881.JPG
📍
🎤 Handles and fixtures of the sliding doors are old and worn out.
Photo 81
Excluded
81/128
14:34 IMG_1882.JPG
📍
🎤 Handles and fixtures of the sliding doors are old and worn out.
Photo 82
Excluded
82/128
14:35 IMG_1883.JPG
📍
🎤 Entering bedroom two, same issues with the handles of the windows.
Photo 83
Excluded
83/128
14:35 IMG_1884.JPG
📍
🎤 Entering bedroom two, same issues with the handles of the windows.
Photo 84
Excluded
84/128
14:35 IMG_1885.JPG
📍
🎤 Sockets in bedroom 2 are connected to the ground.
Photo 85
Excluded
85/128
14:36 IMG_1886.JPG
📍
🎤 Walls of bedroom 2 have some stains and marks on the wall.
Photo 86
Excluded
86/128
14:37 IMG_1887.JPG
📍
🎤 One socket in bedroom two is damaged and reassembled with a weird thing. Very low current, 205.
Photo 87
Excluded
87/128
14:37 IMG_1888.JPG
📍
🎤 One socket in bedroom two is damaged and reassembled with a weird thing. Very low current, 205.
Photo 88
Excluded
88/128
14:37 IMG_1889.JPG
📍
🎤 One socket in bedroom two is damaged and reassembled with a weird thing. Very low current, 205.
Photo 89
Excluded
89/128
14:38 IMG_1890.JPG
📍
🎤 Only the sockets on the bedside table of bedroom two are connected to the ground.
Photo 90
Excluded
90/128
14:38 IMG_1891.JPG
📍
🎤 The socket in bedroom 2 bathroom is connected to the ground.
Photo 91
Excluded
91/128
14:38 IMG_1892.JPG
📍
🎤 Pressure of water in bedroom in bathroom 2 is good.
Photo 92
Excluded
92/128
14:39 IMG_1893.JPG
📍
🎤 The drain of the sink in bathroom two is also not up to the standard, no siphon.
Photo 93
Excluded
93/128
14:40 IMG_1894.JPG
📍
🎤 They have put a separation bar between the shower floor and the rest of the bathroom floor because of an issue with slope and water going out of the shower.
Photo 94
Excluded
94/128
14:40 IMG_1895.JPG
📍
🎤 They have put a separation bar between the shower floor and the rest of the bathroom floor because of an issue with slope and water going out of the shower.
Photo 95
Excluded
95/128
14:40 IMG_1896.JPG
📍
🎤 They have put a separation bar between the shower floor and the rest of the bathroom floor because of an issue with slope and water going out of the shower.
Photo 96
Excluded
96/128
14:42 IMG_1897.JPG
📍
🎤 Shower head of bedroom 2 Messed the block with calcium so not running properly
Photo 97
Excluded
97/128
14:45 IMG_1898.JPG
📍
🎤 Handles of bedroom three also show the same signs of worn out.
Photo 98
Excluded
98/128
14:45 IMG_1899.JPG
📍
🎤 Stains on floor of bedroom 3.
Photo 99
Excluded
99/128
14:45 IMG_1900.JPG
📍
🎤 Sockets on the bedside of bedroom 3 are connected to the ground and working.
Photo 100
Excluded
100/128
14:46 IMG_1901.JPG
📍
🎤 Sorry, the socket on the left bedside is not connected to ground in bedroom 3.
Photo 101
Excluded
101/128
14:47 IMG_1902.JPG
📍
🎤 Socket in bathroom, bedroom 3, connected to ground and working, but wobbly, not fixed correctly to the wall.
Photo 102
Excluded
102/128
14:47 IMG_1903.JPG
📍
🎤 Socket in bathroom, bedroom 3, connected to ground and working, but wobbly, not fixed correctly to the wall.
Photo 103
Excluded
103/128
14:47 IMG_1904.JPG
📍
🎤 Same issue for shower cabin in bedroom 3 and bedroom 2. There is a separation.
Photo 104
Excluded
104/128
14:49 IMG_1905.JPG
📍
🎤 All exhaust fans in bathrooms are noisy.
Photo 105
Excluded
105/128
14:51 IMG_1906.JPG
📍
🎤 Now I'm looking at the pool pom-pom which is located under the deck.
Photo 106
Excluded
106/128
14:51 IMG_1907.JPG
📍
🎤 Now I'm looking at the pool pom-pom which is located under the deck.
Photo 107
Excluded
107/128
14:52 IMG_1908.JPG
📍
🎤 Now I'm looking at the pool pom-pom which is located under the deck.
Photo 108
Excluded
108/128
14:52 IMG_1909.JPG
📍
🎤 Okay, so I don't see any sumpit in the pool pump room. I can see a pump, but no sumpit. There is water inside the pool pump room. Bad electrical connection, no…
Photo 109
Excluded
109/128
14:52 IMG_1910.JPG
📍
🎤 Okay, so I don't see any sumpit in the pool pump room. I can see a pump, but no sumpit. There is water inside the pool pump room. Bad electrical connection, no…
Photo 110
Excluded
110/128
14:52 IMG_1911.JPG
📍
🎤 Okay, so I don't see any sumpit in the pool pump room. I can see a pump, but no sumpit. There is water inside the pool pump room. Bad electrical connection, no…
Photo 111
Excluded
111/128
14:53 IMG_1912.JPG
📍
🎤 Okay, so I don't see any sumpit in the pool pump room. I can see a pump, but no sumpit. There is water inside the pool pump room. Bad electrical connection, no…
Photo 112
Excluded
112/128
14:53 IMG_1913.JPG
📍
🎤 Okay, so I don't see any sumpit in the pool pump room. I can see a pump, but no sumpit. There is water inside the pool pump room. Bad electrical connection, no…
Photo 113
Excluded
113/128
14:54 IMG_1914.JPG
📍
🎤 I
Photo 114
Excluded
114/128
14:55 IMG_1915.JPG
📍
🎤 And drain broken.
Photo 115
Excluded
115/128
14:55 IMG_1916.JPG
📍
🎤 Holes in the floor tiles in master bedroom.
Photo 116
Excluded
116/128
14:55 IMG_1917.JPG
📍
🎤 Holes in the floor tiles in master bedroom.
Photo 117
Excluded
117/128
14:56 IMG_1918.JPG
📍
🎤 Holes in the floor tiles in master bedroom.
Photo 118
Excluded
118/128
14:56 IMG_1919.JPG
📍
🎤 Sockets connected to ground in master bedroom.
Photo 119
Excluded
119/128
14:58 IMG_1920.JPG
📍
🎤 Very strong sewage smell coming from the drain of the bathtub in the master bedroom. Most likely no siphon.
Photo 120
Excluded
120/128
14:58 IMG_1921.JPG
📍
🎤 Very strong sewage smell coming from the drain of the bathtub in the master bedroom. Most likely no siphon.
Photo 121
Excluded
121/128
14:59 IMG_1922.JPG
📍
🎤 Very strong sewage smell coming from the drain of the bathtub in the master bedroom. Most likely no siphon.
Photo 122
Excluded
122/128
15:00 IMG_1923.JPG
📍
🎤 Cabinets in master bathroom starting to get rotten. My suspicion is that there is water that is trapped under the cabinet because of the slope and of the showe…
Photo 123
Excluded
123/128
15:00 IMG_1924.JPG
📍
🎤 Cabinets in master bathroom starting to get rotten. My suspicion is that there is water that is trapped under the cabinet because of the slope and of the showe…
Photo 124
Excluded
124/128
15:01 IMG_1925.JPG
📍
🎤 Sink drain of master bathroom is properly done.
Photo 125
Excluded
125/128
15:02 IMG_1926.JPG
📍
🎤 Sink drain of master bathroom is properly done.
Photo 126
Excluded
126/128
15:03 IMG_1927.JPG
📍
🎤 Issues with the separation in the master bathroom shower cabin, it's broken so the water is going everywhere.
Photo 127
Excluded
127/128
15:03 IMG_1928.JPG
📍
🎤 Issues with the separation in the master bathroom shower cabin, it's broken so the water is going everywhere.
Photo 128
Excluded
128/128
15:05 IMG_1929.JPG
📍
No voice note linked
Loading…